  "schemaVersion": "1.0",
  "module": "A2",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "A2",
    "en": "A2 - A2-e"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/A2/index_de.html",
    "en": "/output/A2/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "en",
      "title": "A2 - A2-e",
      "url": "/output/A2/A2-e_en.html",
      "excerpt": "A2 - A2-e DE A2 A2-e Contents A2-e On this page Safety valve Sizing coefficient (Druckmittelbeiwert) x for steam A2-e Safety valve Fig. 1 D E = Diameter of inlet tract A E = Cross section of inlet tract L E = Stretched length of inlet tract A 0 = Narrowest flow cross-section t K = Isentropic exponent α w = Certified discharged coefficient λ = Friction factors ζ z = Allowable coefficient of resistance ζ i = Coefficient of resistance for piping components and internals K = Equivalent roughness Sizing coefficient (Druckmittelbeiwert) x for steam Fig 4. Sizing coefficient x for steam"
    },
    {
      "language": "de",
      "title": "A2",
      "url": "/output/A2/A2_de.html",
      "excerpt": "A2 EN A2 Navigation A2 Auf dieser Seite Sicherheitsventil Druckmittelbeiwert x für Wasserdampf A2 Sicherheitsventil Bild 1 D E = Durchmesser der Zuleitung A E = Querschnitt der Zuleitung L E = gestreckte Länge der Zuleitung A 0 = engster Strömungsquerschnitt K = Isentropenexponent α w = zuerkannte Ausflussziffer λ = Rohrreibungsbeiwert ζ z = zul. Widerstandsbeiwert ζ i = Widerstandsbeiwert für Leitungs- und Einbauteile K = äquivalente Rauigkeit Druckmittelbeiwert x für Wasserdampf Bild 4. Druckmittelbeiwert x für Wasserdampf"
    }
  ],
  "variables": [],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "A2",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}