{
  "schemaVersion": "1.0",
  "module": "COIL",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "COIL - Beschreibung des Programms",
    "en": "COIL - Program description"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/COIL/index_de.html",
    "en": "/output/COIL/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "de",
      "title": "COIL - Aufbau des Programms",
      "url": "/output/COIL/AufbaudesProgramms_de.html",
      "excerpt": "COIL - Aufbau des Programms EN COIL Aufbau des Programms Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Aufbau des Programms Leistungsumfang COIL Aufbau des Programms Aufbau des Programms Das Programm ist aus Bausteinen (Modulen) des LV Programmsystems ATLAS aufgebaut, die untereinander über die Ein- und Ausgabegrößen verknüpft sind. Jedes Modul stellt ein eigenständiges Programm dar, das über eine Ein-Ausgabe-Oberfläche verfügt. Man unterscheidet nicht zwischen einem getrennten Vorgang für die Dateneingabe und der Berechnung. Das Programmsystem ATLAS ist ein simultanes Dialog- / Berechnungssystem . Jede Vorgabe eines Wertes löst unmittelbar einen Bearbeitungsschritt aus, bis dies aufgrund der Bestimmtheit des Systems nicht mehr möglich und die Lösung erreicht ist. Welcher Wert ein Vorgabewert oder Ergebniswert ist, wird vom Anwender entschieden. Die Grundfunktionen dieses Moduls und die verschiedenen Bearbeitungsregeln sind in der Beschreibung des Programmsystems ATLAS nachzulesen. Leistungsumfang COIL Module Bereich Wärmeübertrager: ACOI Wärmeübertragung bei der Strömung um die Rohrwendeln COIL Berechnung von Rohrwendel-Wärmeübertragern FN Bestimmung des Korrekturfaktors für die logarithmische Temperaturdifferenz Module VDI-Wärmeatlas und Stoffwertmodule: * Zusatzmodule mit Aufpreis. EGAS Stoffwerte von Erdgas H und L, sowie beliebige "
    },
    {
      "language": "de",
      "title": "COIL - Bedienung",
      "url": "/output/COIL/Bedienung_de.html",
      "excerpt": "COIL - Bedienung EN COIL Bedienung Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Start von COIL Auswahl des Wärmeübertrager-Typs Rohrabmessungen Wendelsteigung, Abstand der Windungen und Wendellänge Rohrmaterial Mantelabmessungen Wendeltyp Auswahl der Medien Bibliothek Visual COIL Menü ’Pfade’ Auswahl des Wärmeübertrager-Typs Rohrabmessungen Wendelsteigung, Abstand der Windungen und Wendellänge Rohrmaterial Mantelabmessungen Wendeltyp Auswahl der Medien Bibliothek Visual COIL Auswahl der Grunddaten Auswahl des Wärmeübertrager-Typs Rohrabmessungen Wendelsteigung, Abstand der Windungen und Wendellänge Rohrmaterial Mantelabmessungen Wendeltyp Auswahl der Medien Bibliothek Visual COIL COIL Eingabemaske und Menü \"Grundeingaben\" Auswahl der Grunddaten Spezifikationsblatt Standardwerte Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Bibliothek Geometriedaten einfrieren/editieren Stoffwerte und Wärmebilanz Handeingabe von Stoffwerten \"Freie Eingabe\" Eingabemaske und allgemeine Wärmebilanz Geometrische Daten Ergebnisse und Bewertung Kondensation von beliebigen Reinstoffen Bedienung Start von COIL Starten Sie das Programm unter \"Programme\" / \"Rohrwendel \" / „Rohrschlangen-Wärmeübertrager“ Menü ’Pfade’ In diesem Menü können bei einer Netzwerkinstallation die Pfade für COIL-Grunddaten (Rohre, Teilungen, Mäntel), die Rohrspiegelbibliothek s"
    },
    {
      "language": "de",
      "title": "COIL - Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr)",
      "url": "/output/COIL/BeispielrechnungfüreinenKoaxial-Wärmeübertrager(gewendeltesDoppelrohr)_de.html",
      "excerpt": "COIL - Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) EN COIL Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Im Programm COIL erfolgt die Voreinstellung für die Berechnung eines Koaxial-Wärmeübertragers in der Form \"Auswahl der Grunddaten\" . Diese Form erscheint nach dem Programmstart. Durch Anklicken der Option \"Koaxial-Wärmeübertrager\" im Feld \"Wärmeübertrager-Typ\" werden die Geometriedaten der Rohre sichtbar. Im Feld Rohre sind bereits mehrere Rohrkombinationen für das Außen- und Innenrohr hinterlegt. Diese können vom Anwender selbst mit weiteren Rohrkombinationen erweitert werden. Möchten Sie Rohre verwenden, die nicht in diesen Auswahlboxen enthalten sind, können Sie die Zahlenwerte für den Rohraußendurchmesser und die Wandstärke sowie für den Wendeldurchmesser und die Wendelsteigung in den Eingabefeldern überschreiben. Diese Werte können auch später in der COIL-Maske noch geändert werden. Wählen Sie in dieser Form das rohr- und mantelseitige Medium aus und bestätigen Sie Ihre Wahl mit „OK“. Es öffnet sich die Form „Visual COIL“ "
    },
    {
      "language": "de",
      "title": "COIL - Beschreibung des Programms",
      "url": "/output/COIL/BeschreibungdesProgramms_de.html",
      "excerpt": "COIL - Beschreibung des Programms EN COIL Beschreibung des Programms Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Was kann das Programm? Berechnung von Rohrschlangen-Wärmeübertragern Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Beschreibung des Programms Was kann das Programm? Berechnung von Rohrschlangen-Wärmeübertragern Das Programm COIL dient zur Auslegung, Optimierung, Simulation von Rohrschlangen-Wärmeübertragern. Diese können zur Führung der Strömung um die Wendel mit einem Verdrängungszylinder versehen oder auch ohne Einbauten ausgeführt sein. Die Wendelsteigung, der Rohr- und Manteldurchmesser sind beliebig wählbar. Die Wendel kann aus maximal 5 parallel durchströmten Rohren bestehen. Die Mantelseite ist stets zwangsdurchströmt . Strömungsführung kann Gegenstrom oder Gleichstrom sein. Auf Wunsch rechnet das Programm nur mit normgerechten Rohr- und Mantelabmessungen (Standardwerte ). Dies ermöglicht dem Konstrukteur, ausschließlich Standard-Halbzeuge zu verwenden und dadurch Kosten und Lieferzeiten zu optimieren bzw. die Lagerhaltungskosten durch ein begrenztes Materialsortiment zu redu-zieren. Die Medien sind einphasig (flüssig oder gasförmig) oder kondensierende Reinstoffe (Reinstoffkondensation, Isotherme Kondensation). Die Stoffwerte der eingesetzten Medien werden über LV-Stoffwertmodule bereitg"
    },
    {
      "language": "de",
      "title": "COIL - Bibliothek",
      "url": "/output/COIL/Bibliothek_de.html",
      "excerpt": "COIL - Bibliothek EN COIL Bibliothek Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Bedienung der Bibliothek Rohrspiegel speichern Rohrspiegel laden Standard\">Datenbank / ->Standard Datenbank / wählen Bibliothek Bedienung der Bibliothek Formularansicht nach \"Bibliothek bearbeiten\" Rohrspiegel speichern Dieser Button erscheint, falls die Bibliothek von der COIL-Eingabemaske aus aufgerufen wurde. Alle auf der Eingabemaske von COIL erfolgten Eingaben zur Geometrie des Apparates in die Datenbank werden aufgenommen. Rohrspiegel laden Der aktuelle Datensatz, erkennbar durch den dunkelgrauen Balken über alle Spalten, wird für die Berechnung genutzt. Das bedeutet, die Daten werden in die aktuelle COIL-Maske eingetragen. Dort vorhandene Daten werden in diesem Fall überschrieben. Datenbank / ->Standard Es können verschiedene Bibliothek-Datenbanken angelegt werden. Alle Operationen beziehen sich auf die aktive Datenbank, deren Name im Feld unter \"Datenbank\" eingetragen ist. Die Standarddatenbank ist diejenige, die beim Aktivieren des Formulars verwendet wird. Sie ist durch die gelbe Hintergrundfarbe im Datenbankfeld gekennzeichnet. Mit dem Button \"->Standard\" kann diese Einstellung geändert werden. Datenbank / wählen Mit dieser Funktion kann eine andere Datenbank geladen werden. Ist keine Dateiendung angegeben, wird automatisch \".MDB\" ergänzt. Ist "
    },
    {
      "language": "en",
      "title": "COIL - Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL",
      "url": "/output/COIL/CoaxialTubeHeatExchanger(coileddouble-pipe)inCOIL_en.html",
      "excerpt": "COIL - Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL DE COIL Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Calculation example of a coaxial tube heat exchanger with the COIL program Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Calculation example of a coaxial tube heat exchanger with the COIL program The entries for the calculation of a coaxial tube heat exchanger are done in the mask 'Basic data selection' . This mask is the first mask to appear after program start. By selecting the option Coaxial tube heat exchanger' in the ‘Heat exchanger type’ field, the calculation is initialized. There are several tubes and pipes in the database which can be selected in the selection boxes ' Internal tubes' and ‘External tubes’ . The data of these tubes (outside diameter and wall thickness) can be saved. If you want to use tubes which are not listed in the selection box, you can overwrite the values for outside diameter and wall thickness directly in the fields. You can change the values at a later time in the COIL mask as well. Select the tube-side and shell-side media and confirm your selection by pressing 'OK'. The next mask 'Visual COIL' is displayed. In this mask you may enter your system data for the tube-side and shell-side media. Confirm your entries with 'OK'. The program switches to the COIL inpu"
    },
    {
      "language": "en",
      "title": "COIL - Database",
      "url": "/output/COIL/Database_en.html",
      "excerpt": "COIL - Database DE COIL Database Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Using the database Save Tubesheet Load Tubesheet Standard\">Database / ->Standard Database / Select Database Using the database Save Tubesheet This button is only visible if the database has been called up by the COIL program. All geometrical data of the exchanger entered in the input mask of coil are transferred to the data base. Load Tubesheet The highlighted record is used in the current calculation of COIL. The data are transferred to the COIL program and all data in the input mask are overwritten. Database / ->Standard The tube sheet data can be distributed over different databases. All operations refer to the currently active database, the name of which is entered in the field below \"Data base\". The standard data base is the one used when activating the form. This database is indicated by the yellow background colour in the data base field. This setting can be changed by pressing the button ‘->Standard’ . If the standard database does not exist during the calling up or if no one has been selected yet (in this case coil.mdb is used), automatically a new one with the corresponding name will be created. Database / Select With the help of this function, another database can be loaded. If no file extension has been given, \".MDB\" is automatically added. If a database that has been entered does not"
    },
    {
      "language": "en",
      "title": "COIL - Operation",
      "url": "/output/COIL/Operation_en.html",
      "excerpt": "COIL - Operation DE COIL Operation Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Starting COIL Selection of type of heat exchanger Tube dimensions Coil pitch, distance of windings and coil length Tube material Shell dimensions Coil type Selection of media Data Base Visual COIL Menu ’Path’ Selection of type of heat exchanger Tube dimensions Coil pitch, distance of windings and coil length Tube material Shell dimensions Coil type Selection of media Data Base Visual COIL Selection of basic data Selection of type of heat exchanger Tube dimensions Coil pitch, distance of windings and coil length Tube material Shell dimensions Coil type Selection of media Data Base Visual COIL COIL input mask and basic input menu Basic data selection Specification sheet Default values Set alpha tube-side Set alpha shell-side Data base Geometrical data lock/edit Properties and heat balance Manual input of properties \"Free input\" Input mask and general heat balance Geometrical data Results and evaluation Condensation of any pure substances Operation Starting COIL Start Coil by ‘Programs’ / ‘COIL’ / ‘Coil type heat exchanger’ Menu ’Path’ In this menu, you can determine the network paths for a network installation of COIL. COIL basic data (tubes, pitches, and shells), the tube sheet library and the properties module ‘S-TAB’. Selection of basic data After starting the program the \"Basic data selection"
    },
    {
      "language": "en",
      "title": "COIL - Program description",
      "url": "/output/COIL/Programdescription_en.html",
      "excerpt": "COIL - Program description DE COIL Program description Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Program features Design of Tube Coil Heat Exchangers Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Program description Program features Design of Tube Coil Heat Exchangers With the COIL program, you can design, optimize and simulate tube coil heat exchangers. The exchangers may have a displacement cylinder to guide the flow around the coil or they may not have any internals. The coil pitch, the shell diameter and tube diameter are freely selectable. The coil may consist of a maximum of 5 parallel flown-through tubes . Shell-side flow is always forced flow . Flow direction might be cocurrent or countercurrent. You can also set the program parameters so that the program will only calculate with standard tube and shell dimension s (default values). This enables the constructor to optimize times of delivery or to reduce costs for storage by limiting the assortment of goods. Media must be single phase (liquid or gaseous) or condensing pure substances (pure substance condensation, isothermal condensation). The properties of the used media are provided by LV property modules and are determined for mean temperatures and pressures. Condensation of multi-component mixtures is not possible with COIL. Design of Coaxial Tube Heat Exchangers (coiled double-pipe) This option "
    },
    {
      "language": "en",
      "title": "COIL - Program structure",
      "url": "/output/COIL/Programstructure_en.html",
      "excerpt": "COIL - Program structure DE COIL Program structure Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Structure of the program The modules of COIL Program structure Structure of the program The program consists of units (modules ) of our program system ATLAS, which are linked with each other by input and output variables. Each module represents an independent program provided with an input/output surface. There is no differentiation between a separate data input process and the calculation process. The program system ATLAS is a simultaneous dialogue/calculation system . Each entered value leads automatically to a processing step as long as the system is determined and the solution is found. The user himself/herself can decide which values are given and which values are calculated. The basic functions of this module and the editing rules are described in the manual of the ATLAS program system. The modules of COIL Heat exchanger modules : ACOI Heat transfer around coils COIL Design of coil heat exchangers FN Correction factor for logarithmic temperature difference VDI Heat Atlas and properties modules : EGAS Properties of natural gas type H and L and of any composition FRIG Properties of refrigerants GLYC Properties of glycols (Antifrogens L, N, KF and SOL) H 2 O Properties of water and steam H 2 O Condensation of saturated steam LUFT Properties of air NH 3 Properties of ammonia O"
    },
    {
      "language": "en",
      "title": "COIL - Variable list",
      "url": "/output/COIL/Variablelist_en.html",
      "excerpt": "COIL - Variable list DE COIL Variable list Contents Program description Program structure Operation Database Coaxial Tube Heat Exchanger (coiled double-pipe) in COIL Variable list On this page Variables Variable 3 - Volume flow of inside medium at mean temperature of the medium (ϑei + ϑai)/2 and pressure Pi Variable 4 - Volume flow of outside medium at mean temperature of the medium (ϑea + ϑaa)/2 and Pressure Pa Variable 13 - Heat duty (inside) Variable 14 - Heat duty (outside) Variable 15 - Heat loss Variable 18 - Thermal conductivity of tube material λ Variable 20 - Fouling resistance f Variable 21 - Required exchanger area Variable 22 - Logarithmic mean temperature difference (LMTD) Variable 29 - Mean calculation temperature (inside) Variable 30 - Mean calculation temperature (outside) Variable 35 - Vapor fraction at inlet (inside) Variable 36 - Vapor fraction at inlet (outside) Variable 39 - Pressure at inlet Variable 40 - Pressure at inlet Variable 44 – Coil pitch Variable 53 – Mean flow velocity of medium inside Variable 64 - Pressure drop tube-side Variable 65 - Pressure drop shell-side Variable 72 - Inside diameter of inlet nozzle inside Variable 73 - Inside diameter of outlet nozzle outside Variable 80 - FN Factor Variable 91 – Fouling resistance inside Variable 92 – Fouling resistance inside Variable 94 - Medium velocity shell-side Variable 133 - Actual inlet temperature of medium inside Variable 134 - Actual inlet temperature of medium outside Variable 140 - Standa"
    },
    {
      "language": "de",
      "title": "COIL - Variablenliste",
      "url": "/output/COIL/Variablenliste_de.html",
      "excerpt": "COIL - Variablenliste EN COIL Variablenliste Navigation Beschreibung des Programms Aufbau des Programms Bedienung Bibliothek Beispielrechnung für einen Koaxial-Wärmeübertrager (gewendeltes Doppelrohr) Variablenliste Auf dieser Seite Variablen Variable 3 - Volumenstrom innen bei mittlerer Temperatur des Mediums (ϑei + ϑai)/2 und bei Pi Variable 4 - Volumenstrom außen bei mittlerer Temperatur des Mediums (ϑea + ϑaa)/2 und bei Pa Variable 13 - Leistung innen Variable 14 - Leistung außen Variable 15 - Verlustwärmestrom Variable 18 - Wärmeleitfähigkeit der Rohre λ Variable 20 - Verschmutzungswiderstand f (Foulingfaktor) Variable 21 - Erforderliche Wärmeübertragerfläche Variable 22 - Mittlere logarithmische Temperaturdifferenz Variable 29 - Mittlere Berechnungstemperatur innen Variable 30 - Mittlere Berechnungstemperatur außen Variable 35 - Dampfanteil am Eintritt innen Variable 36 - Dampfanteil am Eintritt außen Variable 39 - Druck ein Variable 40 - Druck ein Variable 44 – Wendelsteigung Variable 53 - Mittlere Strömungsgeschwindigkeit innen Variable 64 - Druckverlust innen Variable 65 - Druckverlust außen Variable 72 - Innendurchmesser des Eintrittsstutzens außen Variable 73 - Innendurchmesser des Austrittsstutzens außen Variable 80 - FN-Faktor Variable 91 – Verschmutzungswiderstand innen Variable 92 – Verschmutzungswiderstand außen Variable 94 - Strömungsgeschwindigkeit außen Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstemperatur"
    }
  ],
  "variables": [
    {
      "varNr": 3,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 3 - Volumenstrom innen bei mittlerer Temperatur des Mediums (ϑei + ϑai)/2 und bei Pi",
        "en": "COIL - Variable 3 - Volume flow of inside medium at mean temperature of the medium (ϑei + ϑai)/2 and pressure Pi"
      },
      "description": {
        "de": "COIL - Variable 3 - Volumenstrom innen bei mittlerer Temperatur des Mediums (ϑei + ϑai)/2 und bei Pi COIL Variable 3 - Volumenstrom innen bei mittlerer Temperatur des Mediums (ϑei + ϑai)/2 und bei Pi Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichst",
        "en": "COIL - Variable 3 - Volume flow of inside medium at mean temperature of the medium (ϑei + ϑai)/2 and pressure Pi COIL Variable 3 - Volume flow of inside medium at mean temperature of the medium (ϑei + ϑai)/2 and pressure Pi Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable3volumenstrominnenbeimittlerertemperaturdesmediumseiai2u_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable3volumeflowofinsidemediumatmeantemperatureofthemediumeia_en.html"
        ]
      }
    },
    {
      "varNr": 4,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 4 - Volumenstrom außen bei mittlerer Temperatur des Mediums (ϑea + ϑaa)/2 und bei Pa",
        "en": "COIL - Variable 4 - Volume flow of outside medium at mean temperature of the medium (ϑea + ϑaa)/2 and Pressure Pa"
      },
      "description": {
        "de": "COIL - Variable 4 - Volumenstrom außen bei mittlerer Temperatur des Mediums (ϑea + ϑaa)/2 und bei Pa COIL Variable 4 - Volumenstrom außen bei mittlerer Temperatur des Mediums (ϑea + ϑaa)/2 und bei Pa Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichst",
        "en": "COIL - Variable 4 - Volume flow of outside medium at mean temperature of the medium (ϑea + ϑaa)/2 and Pressure Pa COIL Variable 4 - Volume flow of outside medium at mean temperature of the medium (ϑea + ϑaa)/2 and Pressure Pa Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tu"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable4volumenstromauenbeimittlerertemperaturdesmediumseaaa2un_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable4volumeflowofoutsidemediumatmeantemperatureofthemediumea_en.html"
        ]
      }
    },
    {
      "varNr": 13,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 13 - Leistung innen",
        "en": "COIL - Variable 13 - Heat duty (inside)"
      },
      "description": {
        "de": "COIL - Variable 13 - Leistung innen COIL Variable 13 - Leistung innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 13 - Heat duty (inside) COIL Variable 13 - Heat duty (inside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - A"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable13leistunginnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable13heatdutyinside_en.html"
        ]
      }
    },
    {
      "varNr": 14,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 14 - Leistung außen",
        "en": "COIL - Variable 14 - Heat duty (outside)"
      },
      "description": {
        "de": "COIL - Variable 14 - Leistung außen COIL Variable 14 - Leistung außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 14 - Heat duty (outside) COIL Variable 14 - Heat duty (outside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 -"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable14leistungauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable14heatdutyoutside_en.html"
        ]
      }
    },
    {
      "varNr": 15,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 15 - Verlustwärmestrom",
        "en": "COIL - Variable 15 - Heat loss"
      },
      "description": {
        "de": "COIL - Variable 15 - Verlustwärmestrom COIL Variable 15 - Verlustwärmestrom Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintri",
        "en": "COIL - Variable 15 - Heat loss COIL Variable 15 - Heat loss Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Actual inlet temper"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable15verlustwrmestrom_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable15heatloss_en.html"
        ]
      }
    },
    {
      "varNr": 18,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 18 - Wärmeleitfähigkeit der Rohre λ",
        "en": "COIL - Variable 18 - Thermal conductivity of tube material λ"
      },
      "description": {
        "de": "COIL - Variable 18 - Wärmeleitfähigkeit der Rohre λ COIL Variable 18 - Wärmeleitfähigkeit der Rohre λ Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 18 - Thermal conductivity of tube material λ COIL Variable 18 - Thermal conductivity of tube material λ Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet tem"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable18wrmeleitfhigkeitderrohre_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable18thermalconductivityoftubematerial_en.html"
        ]
      }
    },
    {
      "varNr": 20,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 20 - Verschmutzungswiderstand f (Foulingfaktor)",
        "en": "COIL - Variable 20 - Fouling resistance f"
      },
      "description": {
        "de": "COIL - Variable 20 - Verschmutzungswiderstand f (Foulingfaktor) COIL Variable 20 - Verschmutzungswiderstand f (Foulingfaktor) Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstempe",
        "en": "COIL - Variable 20 - Fouling resistance f COIL Variable 20 - Fouling resistance f Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable20verschmutzungswiderstandffoulingfaktor_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable20foulingresistancef_en.html"
        ]
      }
    },
    {
      "varNr": 21,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 21 - Erforderliche Wärmeübertragerfläche",
        "en": "COIL - Variable 21 - Required exchanger area"
      },
      "description": {
        "de": "COIL - Variable 21 - Erforderliche Wärmeübertragerfläche COIL Variable 21 - Erforderliche Wärmeübertragerfläche Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseit",
        "en": "COIL - Variable 21 - Required exchanger area COIL Variable 21 - Required exchanger area Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variab"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable21erforderlichewrmebertragerflche_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable21requiredexchangerarea_en.html"
        ]
      }
    },
    {
      "varNr": 22,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 22 - Mittlere logarithmische Temperaturdifferenz",
        "en": "COIL - Variable 22 - Logarithmic mean temperature difference (LMTD)"
      },
      "description": {
        "de": "COIL - Variable 22 - Mittlere logarithmische Temperaturdifferenz COIL Variable 22 - Mittlere logarithmische Temperaturdifferenz Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 22 - Logarithmic mean temperature difference (LMTD) COIL Variable 22 - Logarithmic mean temperature difference (LMTD) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Ac"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable22mittlerelogarithmischetemperaturdifferenz_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable22logarithmicmeantemperaturedifferencelmtd_en.html"
        ]
      }
    },
    {
      "varNr": 29,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 29 - Mittlere Berechnungstemperatur innen",
        "en": "COIL - Variable 29 - Mean calculation temperature (inside)"
      },
      "description": {
        "de": "COIL - Variable 29 - Mittlere Berechnungstemperatur innen COIL Variable 29 - Mittlere Berechnungstemperatur innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrse",
        "en": "COIL - Variable 29 - Mean calculation temperature (inside) COIL Variable 29 - Mean calculation temperature (inside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet tempera"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable29mittlereberechnungstemperaturinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable29meancalculationtemperatureinside_en.html"
        ]
      }
    },
    {
      "varNr": 30,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 30 - Mittlere Berechnungstemperatur außen",
        "en": "COIL - Variable 30 - Mean calculation temperature (outside)"
      },
      "description": {
        "de": "COIL - Variable 30 - Mittlere Berechnungstemperatur außen COIL Variable 30 - Mittlere Berechnungstemperatur außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrse",
        "en": "COIL - Variable 30 - Mean calculation temperature (outside) COIL Variable 30 - Mean calculation temperature (outside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet tempe"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable30mittlereberechnungstemperaturauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable30meancalculationtemperatureoutside_en.html"
        ]
      }
    },
    {
      "varNr": 35,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 35 - Dampfanteil am Eintritt innen",
        "en": "COIL - Variable 35 - Vapor fraction at inlet (inside)"
      },
      "description": {
        "de": "COIL - Variable 35 - Dampfanteil am Eintritt innen COIL Variable 35 - Dampfanteil am Eintritt innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 1",
        "en": "COIL - Variable 35 - Vapor fraction at inlet (inside) COIL Variable 35 - Vapor fraction at inlet (inside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of me"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable35dampfanteilameintrittinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable35vaporfractionatinletinside_en.html"
        ]
      }
    },
    {
      "varNr": 36,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 36 - Dampfanteil am Eintritt außen",
        "en": "COIL - Variable 36 - Vapor fraction at inlet (outside)"
      },
      "description": {
        "de": "COIL - Variable 36 - Dampfanteil am Eintritt außen COIL Variable 36 - Dampfanteil am Eintritt außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 1",
        "en": "COIL - Variable 36 - Vapor fraction at inlet (outside) COIL Variable 36 - Vapor fraction at inlet (outside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of "
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable36dampfanteilameintrittauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable36vaporfractionatinletoutside_en.html"
        ]
      }
    },
    {
      "varNr": 39,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 39 - Druck ein",
        "en": "COIL - Variable 39 - Pressure at inlet"
      },
      "description": {
        "de": "COIL - Variable 39 - Druck ein COIL Variable 39 - Druck ein Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstemperatur Ma",
        "en": "COIL - Variable 39 - Pressure at inlet COIL Variable 39 - Pressure at inlet Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Act"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable39druckein_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable39pressureatinlet_en.html"
        ]
      }
    },
    {
      "varNr": 40,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 40 - Druck ein",
        "en": "COIL - Variable 40 - Pressure at inlet"
      },
      "description": {
        "de": "COIL - Variable 40 - Druck ein COIL Variable 40 - Druck ein Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstemperatur Ma",
        "en": "COIL - Variable 40 - Pressure at inlet COIL Variable 40 - Pressure at inlet Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Act"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable40druckein_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable40pressureatinlet_en.html"
        ]
      }
    },
    {
      "varNr": 44,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 44 - Wendelsteigung",
        "en": "COIL - Variable 44 - Coil pitch"
      },
      "description": {
        "de": "COIL - Variable 44 - Wendelsteigung COIL Variable 44 - Wendelsteigung Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 44 - Coil pitch COIL Variable 44 - Coil pitch Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Actual inlet temp"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable44wendelsteigung_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable44coilpitch_en.html"
        ]
      }
    },
    {
      "varNr": 53,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 53 - Mittlere Strömungsgeschwindigkeit innen",
        "en": "COIL - Variable 53 - Mean flow velocity of medium inside"
      },
      "description": {
        "de": "COIL - Variable 53 - Mittlere Strömungsgeschwindigkeit innen COIL Variable 53 - Mittlere Strömungsgeschwindigkeit innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur ",
        "en": "COIL - Variable 53 - Mean flow velocity of medium inside COIL Variable 53 - Mean flow velocity of medium inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable53mittlerestrmungsgeschwindigkeitinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable53meanflowvelocityofmediuminside_en.html"
        ]
      }
    },
    {
      "varNr": 64,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 64 - Druckverlust innen",
        "en": "COIL - Variable 64 - Pressure drop tube-side"
      },
      "description": {
        "de": "COIL - Variable 64 - Druckverlust innen COIL Variable 64 - Druckverlust innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eint",
        "en": "COIL - Variable 64 - Pressure drop tube-side COIL Variable 64 - Pressure drop tube-side Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variab"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable64druckverlustinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable64pressuredroptubeside_en.html"
        ]
      }
    },
    {
      "varNr": 65,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 65 - Druckverlust außen",
        "en": "COIL - Variable 65 - Pressure drop shell-side"
      },
      "description": {
        "de": "COIL - Variable 65 - Druckverlust außen COIL Variable 65 - Druckverlust außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eint",
        "en": "COIL - Variable 65 - Pressure drop shell-side COIL Variable 65 - Pressure drop shell-side Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Vari"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable65druckverlustauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable65pressuredropshellside_en.html"
        ]
      }
    },
    {
      "varNr": 72,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 72 - Innendurchmesser des Eintrittsstutzens außen",
        "en": "COIL - Variable 72 - Inside diameter of inlet nozzle inside"
      },
      "description": {
        "de": "COIL - Variable 72 - Innendurchmesser des Eintrittsstutzens außen COIL Variable 72 - Innendurchmesser des Eintrittsstutzens außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittst",
        "en": "COIL - Variable 72 - Inside diameter of inlet nozzle inside COIL Variable 72 - Inside diameter of inlet nozzle inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet tempe"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable72innendurchmesserdeseintrittsstutzensauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable72insidediameterofinletnozzleinside_en.html"
        ]
      }
    },
    {
      "varNr": 73,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 73 - Innendurchmesser des Austrittsstutzens außen",
        "en": "COIL - Variable 73 - Inside diameter of outlet nozzle outside"
      },
      "description": {
        "de": "COIL - Variable 73 - Innendurchmesser des Austrittsstutzens außen COIL Variable 73 - Innendurchmesser des Austrittsstutzens außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittst",
        "en": "COIL - Variable 73 - Inside diameter of outlet nozzle outside COIL Variable 73 - Inside diameter of outlet nozzle outside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet t"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable73innendurchmesserdesaustrittsstutzensauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable73insidediameterofoutletnozzleoutside_en.html"
        ]
      }
    },
    {
      "varNr": 80,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 80 - FN-Faktor",
        "en": "COIL - Variable 80 - FN Factor"
      },
      "description": {
        "de": "COIL - Variable 80 - FN-Faktor COIL Variable 80 - FN-Faktor Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittstemperatur Ma",
        "en": "COIL - Variable 80 - FN Factor COIL Variable 80 - FN Factor Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Actual inlet temper"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable80fnfaktor_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable80fnfactor_en.html"
        ]
      }
    },
    {
      "varNr": 91,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 91 - Verschmutzungswiderstand innen",
        "en": "COIL - Variable 91 - Fouling resistance inside"
      },
      "description": {
        "de": "COIL - Variable 91 - Verschmutzungswiderstand innen COIL Variable 91 - Verschmutzungswiderstand innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 91 - Fouling resistance inside COIL Variable 91 - Fouling resistance inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Va"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable91verschmutzungswiderstandinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable91foulingresistanceinside_en.html"
        ]
      }
    },
    {
      "varNr": 92,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 92 - Verschmutzungswiderstand außen",
        "en": "COIL - Variable 92 - Fouling resistance inside"
      },
      "description": {
        "de": "COIL - Variable 92 - Verschmutzungswiderstand außen COIL Variable 92 - Verschmutzungswiderstand außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 92 - Fouling resistance inside COIL Variable 92 - Fouling resistance inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Va"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable92verschmutzungswiderstandauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable92foulingresistanceinside_en.html"
        ]
      }
    },
    {
      "varNr": 94,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 94 - Strömungsgeschwindigkeit außen",
        "en": "COIL - Variable 94 - Medium velocity shell-side"
      },
      "description": {
        "de": "COIL - Variable 94 - Strömungsgeschwindigkeit außen COIL Variable 94 - Strömungsgeschwindigkeit außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 94 - Medium velocity shell-side COIL Variable 94 - Medium velocity shell-side Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside "
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable94strmungsgeschwindigkeitauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable94mediumvelocityshellside_en.html"
        ]
      }
    },
    {
      "varNr": 133,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite",
        "en": "COIL - Variable 133 - Actual inlet temperature of medium inside"
      },
      "description": {
        "de": "COIL - Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite COIL Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 133 - Actual inlet temperature of medium inside COIL Variable 133 - Actual inlet temperature of medium inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inl"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable133tatschlicheeintrittstemperaturrohrseite_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable133actualinlettemperatureofmediuminside_en.html"
        ]
      }
    },
    {
      "varNr": 134,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 134 - Tatsächliche Eintrittstemperatur Mantelseite",
        "en": "COIL - Variable 134 - Actual inlet temperature of medium outside"
      },
      "description": {
        "de": "COIL - Variable 134 - Tatsächliche Eintrittstemperatur Mantelseite COIL Variable 134 - Tatsächliche Eintrittstemperatur Mantelseite Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintritt",
        "en": "COIL - Variable 134 - Actual inlet temperature of medium outside COIL Variable 134 - Actual inlet temperature of medium outside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual i"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable134tatschlicheeintrittstemperaturmantelseite_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable134actualinlettemperatureofmediumoutside_en.html"
        ]
      }
    },
    {
      "varNr": 140,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 140 - Norm-Volumenstrom des Gases außen",
        "en": "COIL - Variable 140 - Standard volume flow shell-side"
      },
      "description": {
        "de": "COIL - Variable 140 - Norm-Volumenstrom des Gases außen COIL Variable 140 - Norm-Volumenstrom des Gases außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite ",
        "en": "COIL - Variable 140 - Standard volume flow shell-side COIL Variable 140 - Standard volume flow shell-side Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of me"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable140normvolumenstromdesgasesauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable140standardvolumeflowshellside_en.html"
        ]
      }
    },
    {
      "varNr": 141,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 141 - Norm-Volumenstrom des Gases innen",
        "en": "COIL - Variable 141 - Standard volume flow tube-side"
      },
      "description": {
        "de": "COIL - Variable 141 - Norm-Volumenstrom des Gases innen COIL Variable 141 - Norm-Volumenstrom des Gases innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite ",
        "en": "COIL - Variable 141 - Standard volume flow tube-side COIL Variable 141 - Standard volume flow tube-side Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medi"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable141normvolumenstromdesgasesinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable141standardvolumeflowtubeside_en.html"
        ]
      }
    },
    {
      "varNr": 142,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 142 - Dampfanteil am Austritt innen",
        "en": "COIL - Variable 142 - Vapor fraction at outlet (inside)"
      },
      "description": {
        "de": "COIL - Variable 142 - Dampfanteil am Austritt innen COIL Variable 142 - Dampfanteil am Austritt innen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 142 - Vapor fraction at outlet (inside) COIL Variable 142 - Vapor fraction at outlet (inside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature o"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable142dampfanteilamaustrittinnen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable142vaporfractionatoutletinside_en.html"
        ]
      }
    },
    {
      "varNr": 143,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 143 - Dampfanteil am Austritt außen",
        "en": "COIL - Variable 143 - Vapor fraction at outlet (outside)"
      },
      "description": {
        "de": "COIL - Variable 143 - Dampfanteil am Austritt außen COIL Variable 143 - Dampfanteil am Austritt außen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable",
        "en": "COIL - Variable 143 - Vapor fraction at outlet (outside) COIL Variable 143 - Vapor fraction at outlet (outside) Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable143dampfanteilamaustrittauen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable143vaporfractionatoutletoutside_en.html"
        ]
      }
    },
    {
      "varNr": 148,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 148 - Anzahl der Rohre in der Wendel",
        "en": "COIL - Variable 148 - Number of tubes in the coil"
      },
      "description": {
        "de": "COIL - Variable 148 - Anzahl der Rohre in der Wendel COIL Variable 148 - Anzahl der Rohre in der Wendel Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variab",
        "en": "COIL - Variable 148 - Number of tubes in the coil COIL Variable 148 - Number of tubes in the coil Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium ins"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable148anzahlderrohreinderwendel_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable148numberoftubesinthecoil_en.html"
        ]
      }
    },
    {
      "varNr": 149,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 149 - Abstand der Windungen",
        "en": "COIL - Variable 149 - Distance of windings"
      },
      "description": {
        "de": "COIL - Variable 149 - Abstand der Windungen COIL Variable 149 - Abstand der Windungen Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächli",
        "en": "COIL - Variable 149 - Distance of windings COIL Variable 149 - Distance of windings Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 1"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable149abstandderwindungen_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable149distanceofwindings_en.html"
        ]
      }
    },
    {
      "varNr": 150,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 150 - Flächenreserve",
        "en": "COIL - Variable 150 - Overdesign"
      },
      "description": {
        "de": "COIL - Variable 150 - Flächenreserve COIL Variable 150 - Flächenreserve Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstemperatur Rohrseite Variable 134 - Tatsächliche Eintrittst",
        "en": "COIL - Variable 150 - Overdesign COIL Variable 150 - Overdesign Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medium inside Variable 134 - Actual inlet te"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable150flchenreserve_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable150overdesign_en.html"
        ]
      }
    },
    {
      "varNr": 163,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 163 - Tatsächliche Austrittstemperatur Rohrseite",
        "en": "COIL - Variable 163 - Real outlet temperature inside"
      },
      "description": {
        "de": "COIL - Variable 163 - Tatsächliche Austrittstemperatur Rohrseite COIL Variable 163 - Tatsächliche Austrittstemperatur Rohrseite Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintrittstem",
        "en": "COIL - Variable 163 - Real outlet temperature inside COIL Variable 163 - Real outlet temperature inside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of medi"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable163tatschlicheaustrittstemperaturrohrseite_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable163realoutlettemperatureinside_en.html"
        ]
      }
    },
    {
      "varNr": 164,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "COIL - Variable 164 - Tatsächliche Austrittstemperatur Mantelseite",
        "en": "COIL - Variable 164 - Real outlet temperature outside"
      },
      "description": {
        "de": "COIL - Variable 164 - Tatsächliche Austrittstemperatur Mantelseite COIL Variable 164 - Tatsächliche Austrittstemperatur Mantelseite Navigation Engineering Your Best Alpha in den Rohren vorgeben Alpha um die Rohre vorgeben Aufbau des Programms Auswahl der Grunddaten Auswahl der Grunddaten Auswahl der Medien Auswahl des Wärmeübertrager-Typs Bedienung der Bibliothek Berechnung eines Koaxial-Wärmeübertragers mit dem Programm COIL Berechnung von gewendelten Doppelrohr-Apparaten (Koaxial-Wärmeübertragern) Berechnung von Rohrschlangen-Wärmeübertragern Bibliothek Bibliothek COIL Eingabemaske und Menü \"Grundeingaben\" Datenbank / ->Standard Datenbank / wählen Doppelrohrwendel Eingabemaske und allgemeine Wärmebilanz Ergebnisse und Bewertung Geometriedaten einfrieren/editieren Geometrische Daten Handeingabe von Stoffwerten \"Freie Eingabe\" Index Kondensation von beliebigen Reinstoffen Leistungsumfang COIL Mantelabmessungen Menü 'Pfade' Rohrabmessungen Rohrmaterial Rohrspiegel laden Rohrspiegel speichern Rohrwendel Spezifikationsblatt Standardwerte Start von COIL Stoffwerte und Wärmebilanz Strömungsrichtung Gegenstrom / Gleichstrom Typische Foulingwiderstände Variable 133 - Tatsächliche Eintritt",
        "en": "COIL - Variable 164 - Real outlet temperature outside COIL Variable 164 - Real outlet temperature outside Contents Engineering Your Best Basic data selection Calculation example of a coaxial tube heat exchanger with the COIL program Coiled double pipes COIL input mask and basic input menu Coil pitch, distance of windings and coil length Coils Coil type Condensation of any pure substances Data base Data Base Database / Select Database / ->Standard Default values Design of Coaxial Tube Heat Exchangers (coiled double-pipe) Design of Tube Coil Heat Exchangers Flow direction Countercurrent / Cocurrent Geometrical data Geometrical data lock/edit Engineering Your Best Index Input mask and general heat balance Load Tubesheet Manual input of properties \"Free input\" Menu 'Path' Program features Properties and heat balance Results and evaluation Save Tubesheet Selection of basic data Selection of media Selection of type of heat exchanger Set alpha shell-side Set alpha tube-side Shell dimensions Specification sheet Starting COIL Structure of the program The modules of COIL Tube dimensions Tube material Typical fouling resistances Using the database Variable 133 - Actual inlet temperature of me"
      },
      "help": {
        "de": [
          "/output/COIL/varhelp/variable164tatschlicheaustrittstemperaturmantelseite_de.html"
        ],
        "en": [
          "/output/COIL/varhelp/variable164realoutlettemperatureoutside_en.html"
        ]
      }
    }
  ],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "COIL",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}
