{
  "schemaVersion": "1.0",
  "module": "EC3C",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "EC3C - Beispiele",
    "en": "EC3C - Examples"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/EC3C/index_de.html",
    "en": "/output/EC3C/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "de",
      "title": "EC3C - Beispiele",
      "url": "/output/EC3C/Beispiele_de.html",
      "excerpt": "EC3C - Beispiele EN EC3C Beispiele Navigation Beispiele Auf dieser Seite Beispiel 1 - Wassergefüllter einschüssiger Zylinder Eingabe der Grunddaten Berechnung der Windlasten Ergebnisse Beispiel 2 - Wassergefüllter dreischüssiger Zylinder Eingabe der Grunddaten Bestimmung des Faktors Kappa (κ) Beulinteraktionsnachweise für alle Schüsse Beispiele Beispiel 1 - Wassergefüllter einschüssiger Zylinder Eingabe der Grunddaten Durchmesser 4000 mm Höhe 8000 mm Wanddicke 5 mm Füllung Wasser bei 50°C Innerer Überdruck 0,1 bar Werkstoff Schale P265GH Berechnung der Windlasten Die Windlasten können z.B. mit dem Modul EC1 (Eurocode 1 Windlasten nach DIN EN 1991-1-4) berechnet werden. Starten Sie hierzu ein neues Modul EC1 und geben die Grunddaten ein. Verbinden Sie das Ergebnis ‚Windkraft‘ und ‚Moment der Windkraft‘ mit dem Modul EC3Cyl. Ergebnisse Wert Beulinteraktionsnachweis ≤ 1 ! Ergebnis Beulinteraktionsnachweis: Nachweis erfüllt. Beispiel 2 - Wassergefüllter dreischüssiger Zylinder Eingabe der Grunddaten Durchmesser 4000 mm Innerer Überdruck 0,1 bar Füllung Wasser bei 50°C Füllhöhe 11000 mm Werkstoff Schale P265GH Schuss 1: Länge 3000 mm Wanddicke 4 mm Schuss 2: Länge 4000 mm Wanddicke 5 mm Schuss 3: Länge 5000 mm Wanddicke 6 mm Bestimmung des Faktors Kappa (κ) Der Faktor Kappa ( κ) muss vom Anwender durch Anwendung der Diagramme in Bild D.6 ermittelt werden. 1.) l a / L = 0,25 (vom Programm berechnet) 2.) t c / t a = 1,5 (vom Programm berechnet) 3.) t b / t a = 1,25 (vom Programm ber"
    },
    {
      "language": "en",
      "title": "EC3C - Examples",
      "url": "/output/EC3C/Examples_en.html",
      "excerpt": "EC3C - Examples DE EC3C Examples Contents Examples On this page Example 1 – Water-filled single section cylinder Basic data Calculating the wind loads Results Example 2 – Water-filled triple section cylinder Basic data Determination of factor Kappa (κ) Buckling interaction check for all sections Examples Example 1 – Water-filled single section cylinder Basic data Diameter 4000 mm Height 8000 mm Wall thickness 5 mm Filling Water at 50°C Positive operating pressure 0.1 bar Shell material P265GH Calculating the wind loads For example you can calculate the wind loads with the EC1 module (Eurocode 1 wind loads acc. to DIN EN 1991-1-4). Start a new EC1 module from the “Project Explorer”‘ and enter the basic data. Connect the results ‚wind force‘ and ‚wind force moment‘ with the EC3Cyl module. Results Value of buckling interaction check ≤ 1 ! Result of buckling interaction check: OK. Example 2 – Water-filled triple section cylinder Basic data Diameter 4000 mm Positive operating pressure 0.1 bar Filing Water at 50°C Filling height 11000 mm Shell material P265GH Section 1: Length 3000 mm Wall thickness 4 mm Section 2: Length 4000 mm Wall thickness 5 mm Section 3: Length 5000 mm Wall thickness 6 mm Determination of factor Kappa (κ) The user must determine factor Kappa ( κ ) by means of using the diagrams in figure D.6. 1.) l a / L = 0,25 (calculated by the program) 2.) t c / t a = 1,5 (calculated by the program) 3.) t b / t a = 1,25 (calculated by the program) Factor Kappa= 0.5 from di"
    }
  ],
  "variables": [],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "EC3Cyl",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}
