{
  "schemaVersion": "1.0",
  "module": "HBB4",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "HBB4",
    "en": "HBB4 - HBB4-e"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/HBB4/index_de.html",
    "en": "/output/HBB4/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "en",
      "title": "HBB4 - HBB4-e",
      "url": "/output/HBB4/HBB4-e_en.html",
      "excerpt": "HBB4 - HBB4-e DE HBB4 HBB4-e Contents HBB4-e On this page eReference Springer Verlag Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient Variable list Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient HBB4-e eReference Springer Verlag VDI Heat Atlas eReference Variable list Variable 67 – Reference heat flux Heat transfer coefficients α 0 and normalized values of the heat flux at tube-side evaporation Heat transfer coefficients α 0 at p 0 * = 0,1, R a0 = 1 · 10 -6 m and normalized values of heat flux q 0 . Medium Formula P c bar M kg/kmol q 0 W/m² α 0 W/m²K Methane CH 4 46,0 16,04 20000 8060 Ethane C 2 H 6 48,8 30,07 20000 5210 Propane C 3 H 8 42,4 44,10 20000 4000 n-Butane C 4 H 10 38,0 58,12 20000 3300 n-Pentane C 5 H 12 33,7 72,15 20000 3070 Isopentane C 5 H 12 33,3 72,15 20000 2940 n-Hexane C 6 H 14 29,7 86,18 20000 2840 n-Heptane C 7 H 16 27,3 100,20 20000 2420 Cyclohexane C 6 H 12 40,8 84,16 20000 2420 Benzene C 6 H 6 48,9 78,11 20000 2730 Toluene C 7 H 8 41,1 92,14 20000 2910 Diphenyl C 12 H 10 38,5 154,21 20000 2030 Methanol CH 4 O 81,0 32,04 20000 4980 Ethanol C 2 H 6 O 63,8 46,07 20000 3690 n-Propanol C 3 H 8 O 51,7 60,10 20000 3170 Isopropanol C 3 H 8 O 47,6 60,10 20000 2920 n-Butanol C 4 H 10 O 49,6 74,12 20000 2750 Isobutanol C 4 H 10 O 43,0 74,12 20000 2940 Acetone C 3 H 6 O 47,0 58,08 "
    },
    {
      "language": "de",
      "title": "HBB4",
      "url": "/output/HBB4/HBB4_de.html",
      "excerpt": "HBB4 EN HBB4 Navigation HBB4 Auf dieser Seite eReference Springer Verlag Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient Variablenliste Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient HBB4 eReference Springer Verlag Zum Springer Wärmeatlas 11. Auflage Variablenliste Variable 67 – Normwärmestromdichte Wärmeübergangskoeffizienten α 0 bei p 0 * = 0,1, R a0 = 1 · 10 -6 m und Normierungswerte der Wärmestromdichte q 0 . Stoff Formel P c bar M kg/kmol q 0 W/m² α 0 W/m²K Methan CH 4 46,0 16,04 20000 8060 Ethan C 2 H 6 48,8 30,07 20000 5210 Propan C 3 H 8 42,4 44,10 20000 4000 n-Butan C 4 H 10 38,0 58,12 20000 3300 n-Pentan C 5 H 12 33,7 72,15 20000 3070 Isopentan C 5 H 12 33,3 72,15 20000 2940 n-Hexan C 6 H 14 29,7 86,18 20000 2840 n-Heptan C 7 H 16 27,3 100,20 20000 2420 Cyclohexan C 6 H 12 40,8 84,16 20000 2420 Benzol C 6 H 6 48,9 78,11 20000 2730 Toluol C 7 H 8 41,1 92,14 20000 2910 Di phenyl C 12 H 10 38,5 154,21 20000 2030 Methanol CH 4 O 81,0 32,04 20000 4980 Ethanol C 2 H 6 O 63,8 46,07 20000 3690 n-Propanol C 3 H 8 O 51,7 60,10 20000 3170 Isopropanol C 3 H 8 O 47,6 60,10 20000 2920 n-Butanol C 4 H 10 O 49,6 74,12 20000 2750 Isobutanol C 4 H 10 O 43,0 74,12 20000 2940 Aceton C 3 H 6 O 47,0 58,08 20000 3270 Fluortrichlormethan CFCI 3 (R 11) 44,0 137,37 20000 2690 Difluordichlormethan"
    }
  ],
  "variables": [
    {
      "varNr": 67,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "HBB4 - Variable 67 – Normwärmestromdichte",
        "en": "HBB4 - Variable 67 – Reference heat flux"
      },
      "description": {
        "de": "HBB4 - Variable 67 – Normwärmestromdichte HBB4 Variable 67 – Normwärmestromdichte Navigation eReference Springer Verlag Engineering Your Best Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient Variablenliste Engineering Your Best Variable 67 – Normwärmestromdichte Variable 67 – Normwärmestromdichte Wärmeübergangskoeffizienten α 0 bei p 0 * = 0,1, R a0 = 1 · 10 -6 m und Normierungswerte der Wärmestromdichte q 0 . Stoff Formel P c bar M kg/kmol q 0 W/m² α 0 W/m²K Methan CH 4 46,0 16,04 20000 8060 Ethan C 2 H 6 48,8 30,07 20000 5210 Propan C 3 H 8 42,4 44,10 20000 4000 n-Butan C 4 H 10 38,0 58,12 20000 3300 n-Pentan C 5 H 12 33,7 72,15 20000 3070 Isopentan C 5 H 12 33,3 72,15 20000 2940 n-Hexan C 6 H 14 29,7 86,18 20000 2840 n-Heptan C 7 H 16 27,3 100,20 20000 2420 Cyclohexan C 6 H 12 40,8 84,16 20000 2420 Benzol C 6 H 6 48,9 78,11 20000 2730 Toluol C 7 H 8 41,1 92,14 20000 2910 Di phenyl C 12 H 10 38,5 154,21 20000 2030 Methanol CH 4 O 81,0 32,04 20000 4980 Ethanol C 2 H 6 O 63,8 46,07 20000 3690 n-Propanol C 3 H 8 O 51,7 60,10 20000 3170 Isopropanol C 3 H 8 O 47,6 60,10 20000 2920 n-Butan",
        "en": "HBB4 - Variable 67 – Reference heat flux HBB4 Variable 67 – Reference heat flux Contents eReference Springer Verlag Engineering Your Best Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient Variable list Engineering Your Best Variable 67 – Reference heat flux Variable 67 – Reference heat flux Heat transfer coefficients α 0 and normalized values of the heat flux at tube-side evaporation Heat transfer coefficients α 0 at p 0 * = 0,1, R a0 = 1 · 10 -6 m and normalized values of heat flux q 0 . Medium Formula P c bar M kg/kmol q 0 W/m² α 0 W/m²K Methane CH 4 46,0 16,04 20000 8060 Ethane C 2 H 6 48,8 30,07 20000 5210 Propane C 3 H 8 42,4 44,10 20000 4000 n-Butane C 4 H 10 38,0 58,12 20000 3300 n-Pentane C 5 H 12 33,7 72,15 20000 3070 Isopentane C 5 H 12 33,3 72,15 20000 2940 n-Hexane C 6 H 14 29,7 86,18 20000 2840 n-Heptane C 7 H 16 27,3 100,20 20000 2420 Cyclohexane C 6 H 12 40,8 84,16 20000 2420 Benzene C 6 H 6 48,9 78,11 20000 2730 Toluene C 7 H 8 41,1 92,14 20000 2910 Diphenyl C 12 H 10 38,5 154,21 20000 2030 Methanol CH 4 O 81,0 32,04 20000 4980 Ethanol C 2 H 6 O 63,8 46,07 20000 3690 n-Propano"
      },
      "help": {
        "de": [
          "/output/HBB4/varhelp/variable67normwrmestromdichte_de.html"
        ],
        "en": [
          "/output/HBB4/varhelp/variable67referenceheatflux_en.html"
        ]
      }
    },
    {
      "varNr": 68,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "HBB4 - Variable 68 – Stoffart",
        "en": "HBB4 - Variable 68 – Type of substance"
      },
      "description": {
        "de": "HBB4 - Variable 68 – Stoffart HBB4 Variable 68 – Stoffart Navigation eReference Springer Verlag Engineering Your Best Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient Variablenliste Engineering Your Best Variable 68 – Stoffart Variable 68 – Stoffart Kryogene Stoffe sind hier Tief- und Tiefstsieder mit Siedetemperaturen < 180 K, z.B. N 2 , H 2 , He. Ausgenommen : Methan, Ethan",
        "en": "HBB4 - Variable 68 – Type of substance HBB4 Variable 68 – Type of substance Contents eReference Springer Verlag Engineering Your Best Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient Variable list Engineering Your Best Variable 68 – Type of substance Variable 68 – Type of substance Cryogenic substances here are substances with boiling temperatures < 180 K, e.g. N 2 , H 2 , He. Except : Methane, Ethane"
      },
      "help": {
        "de": [
          "/output/HBB4/varhelp/variable68stoffart_de.html"
        ],
        "en": [
          "/output/HBB4/varhelp/variable68typeofsubstance_en.html"
        ]
      }
    },
    {
      "varNr": 74,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "HBB4 - Variable 74 – Korrekturfaktor CF",
        "en": "HBB4 - Variable 74 – Correction factor CF"
      },
      "description": {
        "de": "HBB4 - Variable 74 – Korrekturfaktor CF HBB4 Variable 74 – Korrekturfaktor CF Navigation eReference Springer Verlag Engineering Your Best Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient Variablenliste Engineering Your Best Variable 74 – Korrekturfaktor CF Variable 74 – Korrekturfaktor C F CF Faktor für untersuchte Stoffe im senkrechten Rohr Stoff H 2 (Para) He NH 3 H 2 O N 2 R22 R134a R12 R116 SF 6 R113 C F 0,35 0,86 1,24 0,72 0,8 1,2 1,67 b 1,21 2,49 b 2,07 b 2,2 Stoff Methanol Ethanol n-Butanol Benzol Cyclo­hexan n-Pentan n-Heptan R11 C F 0,918 1,013 1,151 1,168 1,191 1,143 1,249 1,36 b Lokale Messwerte für voll benetztes Verdampferrohr © Springer Verlag Berlin Heidelberg 2013",
        "en": "HBB4 - Variable 74 – Correction factor CF HBB4 Variable 74 – Correction factor CF Contents eReference Springer Verlag Engineering Your Best Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient Variable list Engineering Your Best Variable 74 – Correction factor CF Variable 74 – Correction factor C F C F Factor for investigated substances in vertical tubes Substance H 2 (Para) He NH 3 H 2 O N 2 R22 R134a R12 R116 SF 6 R113 C F 0,35 0,86 1,24 0,72 0,8 1,2 1,67 b 1,21 2,49 b 2,07 b 2,2 Substance Methanol Ethanol n-Butanol Benzene Cyclo­hexane n-Pentane n-Heptane R11 C F 0,918 1,013 1,151 1,168 1,191 1,143 1,249 1,36 b Local measurements for fully wetted vaporizer tube © Springer Verlag Berlin Heidelberg 2013"
      },
      "help": {
        "de": [
          "/output/HBB4/varhelp/variable74korrekturfaktorcf_de.html"
        ],
        "en": [
          "/output/HBB4/varhelp/variable74correctionfactorcf_en.html"
        ]
      }
    },
    {
      "varNr": 91,
      "semanticStatus": "legacy-help-only",
      "label": {
        "de": "HBB4 - Variable 91 – Normierungswert Wärmeübergangskoeffizient",
        "en": "HBB4 - Variable 91 – Heat transfer coefficient"
      },
      "description": {
        "de": "HBB4 - Variable 91 – Normierungswert Wärmeübergangskoeffizient HBB4 Variable 91 – Normierungswert Wärmeübergangskoeffizient Navigation eReference Springer Verlag Engineering Your Best Variable 67 – Normwärmestromdichte Variable 68 – Stoffart Variable 74 – Korrekturfaktor CF Variable 91 – Normierungswert Wärmeübergangskoeffizient Variablenliste Engineering Your Best Variable 91 – Normierungswert Wärmeübergangskoeffizient Variable 91 – Normierungswert Wärmeübergangskoeffizient s. Variable 67 – Normwärmestromdichte",
        "en": "HBB4 - Variable 91 – Heat transfer coefficient HBB4 Variable 91 – Heat transfer coefficient Contents eReference Springer Verlag Engineering Your Best Variable 67 – Reference heat flux Variable 68 – Type of substance Variable 74 – Correction factor CF Variable 91 – Heat transfer coefficient Variable list Engineering Your Best Variable 91 – Heat transfer coefficient Variable 91 – Heat transfer coefficient s. Variable 67 – Reference heat flux"
      },
      "help": {
        "de": [
          "/output/HBB4/varhelp/variable91normierungswertwrmebergangskoeffizient_de.html"
        ],
        "en": [
          "/output/HBB4/varhelp/variable91heattransfercoefficient_en.html"
        ]
      }
    }
  ],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "H3.5.2.1",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}
