{
  "schemaVersion": "1.0",
  "module": "S31",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "S31",
    "en": "S31"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/S31/index_de.html",
    "en": "/output/S31/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "de",
      "title": "S31",
      "url": "/output/S31/S31_de.html",
      "excerpt": "S31 EN S31 Navigation S31 Auf dieser Seite Auszug aus DIN 28082 S31 Auszug aus DIN 28082 Ausführung D Doppelring mit Stegen Ausführung P Fußring und Pratzen a) Einzelheiten der Schweißnähte sind in dieser Norm nicht festgelegt c 3 ≈ c2 Fmax = Zugkraft je Ankerschraube 2) Für die Anbringung der Blitzschutzerdung bis Nenndurchmesser 1 000 mm eine Bohrung, darüber zwei diametral gegenüberliegende Bohrungen Bild 2: Fußring (dargestellt ist Ausführung S) Ausführung S mit Ankerschlitz Ausführung L mit Ankerbohrung Dargestellt Fußring mit Pratzen Ankerschlitz bzw. -bohrung achsenfrei gesetzt und symmetrisch zur Hauptachse angeordnet. Bild 3: Ausführung S mit Ankerschlitz und Ausführung L mit Ankerbohrung Wird der lichte Abstand zwischen den Ankerpratzen kleiner als 1,5mal Plattenbreite (f 2 ), so ist hier aus konstruktiven Gründen ein geschlossener Ring (Doppelring) zu verwenden. Tabelle 1: Maße und Ankerschraubenkräfte Das Maß s 1 (siehe Bild 2) muss bei der statischen Berechnung ermittelt werden und muss auch mit den Reaktionskräften aus der Verankerung überprüft werden. Schrauben- gewinde c 1 c 2 d 6 d 7 e f 1 f 2 g h 7 s 2 s 4 s 5 F max kN 1 0038 1 0570 M24 80 60 28 32 60 120 180 45 300 35 25 12 35,4 53,1 M30 95 75 35 40 70 130 190 55 56,6 84,9 M36 110 85 42 48 80 160 220 65 16 82,8 124,2 M42 125 100 48 54 90 170 250 75 400 40 30 102,1 154,4 M48 140 110 56 64 100 180 260 85 134,6 203,4 M56 155 125 66 76 120 220 300 95 45 35 20 186,2 281,4 M64 175 140 74 84 130 230 330 105 500 50"
    },
    {
      "language": "en",
      "title": "S31",
      "url": "/output/S31/S31_en.html",
      "excerpt": "S31 DE S31 Contents S31 On this page Extract from DIN 28082 S31 Extract from DIN 28082 Execution D Double ring with bars Execution P Foot ring and brackets a) details of the welds are not specified in this standard c3 ≈ c2 Fmax = Tensile force per anchor bolt 2) For the attachment of the lightning protection grounding up to nominal diameter 1 000 mm one hole, above this two diametrically opposite holes. Fig. 2: Foot ring (version S is shown) Version S with anchor slot Version Lwith anchor hole Shown foot ring with claws Anchor slot or anchor hole set off-axis and arranged symmetrically to the main axis. Fig. 3: Design S with anchor slot and design L with anchor hole If the clear distance between the anchor claws is less than 1.5 times the plate width (f2), a closed ring (double ring) must be used here for design reasons. Table 1: Dimensions and anchor bolt forces The dimension s1 (see Fig. 2) must be determined in the static calculation and must also be checked with the reaction forces from the anchorage. Screws- thread c1 c2 d6 d7 e f1 f2 g h7 s2 s4 s5 Fmax kN 1 0038 1 0570 M24 80 60 28 32 60 120 180 45 300 35 25 12 35,4 53,1 M30 95 75 35 40 70 130 190 55 56,6 84,9 M36 110 85 42 48 80 160 220 65 16 82,8 124,2 M42 125 100 48 54 90 170 250 75 400 40 30 102,1 154,4 M48 140 110 56 64 100 180 260 85 134,6 203,4 M56 155 125 66 76 120 220 300 95 45 35 20 186,2 281,4 M64 175 140 74 84 130 230 330 105 500 50 40 246,3 372,3 M72 x 6 195 155 82 92 140 240 340 115 55 45 321,2 485,6 M80 x"
    }
  ],
  "variables": [],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "S31",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}
