{
  "schemaVersion": "1.0",
  "module": "S33",
  "contentVersion": "legacy-e619f6b1db68",
  "supportLevel": "legacy-bootstrap",
  "title": {
    "de": "S33",
    "en": "S33"
  },
  "summary": {
    "de": "Bestehende LVS-Modulhilfe. Variablen und Bedienregeln müssen vor Änderungen mit dem aktuellen MCP-Laufzeitzustand abgeglichen werden.",
    "en": "Existing LVS module help. Variables and operating rules must be reconciled with current MCP runtime state before making changes."
  },
  "humanHelp": {
    "de": "/output/S33/index_de.html",
    "en": "/output/S33/index_en.html"
  },
  "knowledgeBase": null,
  "helpTopics": [
    {
      "language": "de",
      "title": "S33",
      "url": "/output/S33/S33_de.html",
      "excerpt": "S33 EN S33 Navigation S33 Auf dieser Seite Zusatzlasten Beispiel: Verlauf der Vergleichsspannung im Boden über den Innendruck Apparate mit Tragfüßen S33 Zusatzlasten Bitte beachten Sie Zusatzlasten wie z.B. Wind und Erdbeben, aber auch Torsionsmomente aus Rührwerken. WICHTIG: Diese Zusatzlasten müssen gegebenenfalls für beide Zustände (drucklos und mit Innendruck beaufschlagt) nachgewiesen werden. Beispiel: Verlauf der Vergleichsspannung im Boden über den Innendruck Der Innendruck wird von 0 bar bis 20 bar variiert. Mit zunehmendem Druck nimmt die Vergleichsspannung zunächst ab, da der Innendruck stützend wirkt. Die Vergleichsspannung erreicht bei ca. 7 bar ein Minimum. Danach steigt die Vergleichsspannung wieder an, da die Druckspannung nun dominierend wird. (Erstellt mit LV Atlas Option 'Parameter Studie') Apparate mit Tragfüßen aus: Eberhard Wegener, Festigkeitsberechnung Verfahrenstechnischer Apparate, Wiley-VCH Verlag GmbH Weinheim 2002 Vertikal angeordnete, auf Fundamenten stehende Apparate werden mit Tragfüßen ausgerüstet. Diese können aus Rohr bestehen, senkrecht oder geneigt, mit oder ohne Verstärkungsblech am gewölbten Boden, oder aus Profilstahl, mit Verstärkungsplatte am zylindrischen Mantel angeschweißt, ausgeführt werden. Für Apparatefüße gelten die DIN 28 081 T. 1 bis DIN 28 081 T4, wobei DIN 28 081 T. 1 nur auf senkrecht angeordnete Tragfüße aus Rohr beschränkt bleibt. Die zum Apparatedurchmesser gehörenden Abmessungen der Tragrohre, des Verstärkungsbleches, d"
    },
    {
      "language": "en",
      "title": "S33",
      "url": "/output/S33/S33_en.html",
      "excerpt": "S33 DE S33 Contents S33 On this page Additional loads Example: Course of the equivalent stress in the soil over the internal pressure Apparatus with supporting feet S33 Additional loads Please consider additional loads such as wind and earthquakes, but also torsional moments from agitators. IMPORTANT: These additional loads must be verified for both conditions (depressurized and pressurized), if applicable. Example: Course of the equivalent stress in the soil over the internal pressure The internal pressure is varied from 0 bar to 20 bar. As the pressure increases, the equivalent stress initially decreases because the internal pressure has a supporting effect. The equivalent stress reaches a minimum at approx. 7 bar. After this, the equivalent stress increases again, as the compressive stress now becomes dominant. (Created with LV Atlas option 'Parameter study') Apparatus with supporting feet from: Eberhard Wegener, Festigkeitsberechnung Verfahrenstechnischer Apparate, Wiley-VCH Verlag GmbH Weinheim 2002 Vertical apparatuses placed on foundations are equipped with supporting feet. These can be made of tube, vertical or inclined, with or without reinforcing plate on the curved base, or of sectional steel, with reinforcing plate welded to the cylindrical shell. DIN 28 081 T. 1 to DIN 28 081 T4 apply to apparatus feet, with DIN 28 081 T. 1 being restricted to vertically arranged support feet made of tube. The dimensions of the supporting tubes, the reinforcing plate, the base pl"
    }
  ],
  "variables": [],
  "mcp": {
    "readBeforeUse": true,
    "workflow": [
      "Read this context and the human module help.",
      "Inspect the live module definition and current values through MCP.",
      "Resolve materials through the material workflow when material selectors are present.",
      "Set only runtime-confirmed input variables; never infer writable state from a legacy help filename.",
      "Calculate, inspect validation messages and read back governing results."
    ],
    "limitations": [
      "This bootstrap context preserves the complete legacy help but does not yet contain a curated semantic variable contract.",
      "Runtime MCP metadata is authoritative when it differs from this legacy snapshot."
    ]
  },
  "migration": {
    "curated": false,
    "target": "Create content/modules/<MODULE>/module.json and bilingual HTML fragments using B1 as the reference.",
    "sourceRepository": "lvs",
    "sourceCommit": "e619f6b1db68045fa49935d6f5f807b9acd1bc1d",
    "catalogConfigurations": [
      {
        "configId": "",
        "displayName": "S33",
        "designType": null,
        "defaultBauform": null
      }
    ]
  }
}
