DE

On this page

S31

Extract from DIN 28082

Execution D

Double ring with bars

Execution P

Foot ring and brackets

 

a) details of the welds are not specified in this standard

c3 ≈ c2

Fmax = Tensile force per anchor bolt

2) For the attachment of the lightning protection grounding up to nominal diameter 1 000 mm one hole, above this two diametrically opposite holes.

Fig. 2: Foot ring (version S is shown)

Version S
with anchor slot

Version Lwith
anchor hole

Shown foot ring with claws

Anchor slot or anchor hole set off-axis and arranged symmetrically to the main axis.

 

 

Fig. 3: Design S with anchor slot and design L with anchor hole

If the clear distance between the anchor claws is less than 1.5 times the plate width (f2), a closed ring (double ring) must be used here for design reasons.

Table 1: Dimensions and anchor bolt forces

The dimension s1 (see Fig. 2) must be determined in the static calculation and must also be checked with the reaction forces from the anchorage.

Screws-
thread

c1

c2

d6

d7

e

f1

f2

g

h7

s2

s4

s5

Fmax
kN

1 0038

1 0570

M24

80

60

28

32

60

120

180

45

300

35

25

12

35,4

53,1

M30

95

75

35

40

70

130

190

55

56,6

84,9

M36

110

85

42

48

80

160

220

65

16

82,8

124,2

M42

125

100

48

54

90

170

250

75

400

40

30

102,1

154,4

M48

140

110

56

64

100

180

260

85

134,6

203,4

M56

155

125

66

76

120

220

300

95

45

35

20

186,2

281,4

M64

175

140

74

84

130

230

330

105

500

50

40

246,3

372,3

M72 x 6

195

155

82

92

140

240

340

115

55

45

321,2

485,6

M80 x 6

215

165

93

106

160

280

380

125

60

50

25

405,0

612,2

1) Material no. according to DIN EN 10025

2) The dimensions s2, s4, s5 are reference values for the project planning phase only. In the case of an order, they can be determined by calculation in accordance with AD leaflet S 3/1. The geometric conditions required therein must also be observed.

The values for the maximum tensile force of the anchor bolt Fmax in Table 1 were determined with the yield strengths fy,b,k at 20°C, a safety factor S = 2.2 and the core cross-section according to DIN 13-28

General tolerances according to 28007-1 and DIN 8570-D

Form A

Basket arch shape

Form B

Dished arch form

 

B-B enlarged

Foot ring with anchor hole

Foot ring with anchor slot

Stand frame opening rotated by 90

 

 

 

 

 

1 frame

5 Reference line

 

2 Foot ring

6 Anchor slot

Set free of axes and arranged symmetrically to the main axis

3 Inspection opening with edge reinforcement

7 Anchor hole

4 Ventilation holes: Up to nominal diameter 1 000 mm at least 2 pieces, diameter 60 mm, from nominal diameter 11 00 mm 4 pieces, diameter 1 00 mm. The ventilation holes must be arranged as high as possible.

8 Connection for grounding for form A and form B

 

1) dimensions to be specified b3, b4 and s3

 

Figure 1: Apparatus with curved bottom