SOL ALPHA Help
Deutsch

Operation and variables

Recommended input order

  1. Select the variant. Cylinder = bauform 1, sphere = bauform 2. MCP clients set variant or bauform in the fill plan and do not write V38.
  2. Enter geometry and loads. Diameter, temperature, operating pressure, test pressure, wall thickness and cylinder length.
  3. Select the material. It must provide K and K' at the current conditions.
  4. Review coefficients. S, S', v, c1, c2 and density must not be copied uncritically.
  5. Calculate and assess. Check calculation success and warnings, then compare V1 with V9 and review V36/V37.

Core inputs

VarKeyUnitNote
V2outsideDiametermmoutside diameter
V24temperature°Ccontrols material strength
V3 / V16pressure / testPressurebarnot MPa
V22materialLV IDuse material server
V9wallThicknessmmexecuted thickness
V10lengthmmrequired for cylinders

Calculated values are read-only

V1, V18, V19, V27, V31, V34, V35, V36 and V37 are results or derived values. A client must never set them as inputs.