Verified reference case
MCP verified on 2026-08-28
This case was run through the semantic B1 fill plan against a live local LV-Atlas-Web session. It is an integration reference, not a general design recommendation.
Inputs
| Variant | Cylinder / 1 | Material | LV ID 1232, 1.4571(P) |
|---|---|---|---|
| Da | 600 mm | T | 120 °C |
| p / p' | 1.5 / 2 bar | se / L | 8 / 2000 mm |
| S / S' / v | 1.5 / 1.05 / 1 | c1 / c2 | 0.3 / 0 mm |
| K / K' | 218 / 260 N/mm² | Density | 7.98 t/m³ |
Expected results
| Result | Variable | Value |
|---|---|---|
| governing thickness | V1 | 0.60947335 mm |
| operating case | V18 | 0.60947335 mm |
| test case | V19 | 0.54220986 mm |
| thickness without allowances | V31 | 7.7 mm |
| allowable operating pressure | V36 | 37.787155 bar |
| allowable test pressure | V37 | 64.38179 bar |
| inside diameter | V27 | 584 mm |
| outside / inside volume | V34 / V35 | 0.56548667 / 0.5357295 m³ |
Expected verdict: calculation successful, operating case governing, executed thickness sufficient. Comparison tolerance: absolute 0.0001 and relative 0.00001.