Validation and troubleshooting
Quick checks
- Is the correct variant loaded?
- Are all required values known in documented units?
- Are material ID, K and K' resolved for the current conditions?
- Was
calculation.successtrue and are there warnings or interactions? - Are V1, V18, V19, V36 and V37 known and calculated?
Typical symptoms
| Symptom | Likely cause | Action |
|---|---|---|
| roughly factor-ten error | bar/MPa confusion | supply V3 and V16 in bar |
| K or K' empty | missing material resolution | check V22, V24, V9, V2 and AD2000 |
| V1/V36/V37 unknown | missing input or failed calculation | validate plan and calculation response |
| wrong variant | V38 conflicts with bauform | use only plan variant/bauform |
| empty material display but K/K' exist | selection state and numeric fallback restored differently | inspect V22 independently |
AI report
An AI report names inputs and units, material ID and strengths, calculation success, warnings, governing case, required and executed wall thickness and allowable pressures. Assumptions and unverified code questions are explicit.